Fluke 1672 Installation Multifunction Tester

Fluke logo

The Fluke 1672 Installation Multifunction Tester – A single solution for all your basic installation testing needs — simplified setup, faster testing.

  • Ergonomic design with a high-resolution colour touchscreen
  • Complies with IEC 60364 and IEC 61557 safety standards
  • Integrated data management for accurate and efficient reporting
  • Suitable for domestic, commercial, and industrial applications

    Fluke 1670 Series Datasheet

    Fluke 1670 Series User Manual

If you would like more information regarding this product, simply email us here.

  • Enter your query
  • Drop files here or
    Accepted file types: jpg, gif, png, pdf, Max. file size: 1 MB, Max. files: 4.
    • This field is for validation purposes and should be left unchanged.

    Fluke 1672 Multifunction Installation Tester

    The Fluke 1672 Multifunction Installation Tester boosts the efficiency of electrical testing with its ergonomic design and advanced capabilities. Engineered to handle the demands of domestic, commercial, and industrial electrical systems, this tester meets the rigorous safety standards of IEC 60364 and IEC 61557.

    It’s user-friendly interface and high-resolution color touchscreen simplify setup and testing, making it easy to navigate complex scenarios.

    With its lightweight yet sturdy construction, the Fluke 1672 is ideal for any setting, from small residential projects to large industrial tasks. It combines flexibility and reliability to ensure electrical systems are safe and compliant, setting a new benchmark for multifunction installation testing.

    Features

    Comparison of the Fluke 1670 series

    1672 1673 FC 1674 FC
    Full-color touch screen
    Insulation PreTest safety function
    Insulation at L-N, L-PE, N-PE inputs
    Auto Test sequence
    Auto pass/fail results
    Loop and line impedance — mΩ resolution
    Continuity at L-N, L-PE, N-PE inputs
    Test smooth DC sensitive RCDs (Type B/B+)
    Earth resistance
    Voltage AC, DC, and frequency
    Wiring polarity checker, detects broken PE and N wires
    Insulation resistance
    Continuity and resistance
    Measure motor windings with continuity test (@ 10 mA)
    Loop and line impedance
    Prospective Earth Fault Current (PEFC/IK)
    Prospective Short-Circuit Current (PSC/IK)
    RCD trip time
    RCD trip current (ramp test)
    Measures trip time and current for RCD type AC, A, and F in one test
    RCD variable test current
    Automatic RCD test sequence
    Phase sequence test
    Voltage drop measurement
    Insulation Monitoring Device (IMD) test
    Surge Protection Device (SPD) test
    Other features
    Fluke Connect compatibility
    Fluke Cloud storage
    On/Off switchable Auto Start for continuity, RCD, and loop test
    Illuminated display
    Memory, interface
    Z Max memory
    Memory
    USB-C, and BLE interface USB-C USB-C/BLE USB-C/BLE

    Specifications

    Specifications: Fluke 1670 Series Multifunction Installation Testers

    General Specifications

    Specification Characteristic
    Size 26.25 cm x 14.19 cm x 11.93 cm (10.3 in x 5.6 in x 4.7 in)
    Weight (incl. batteries) 1.6 kg (3.5 lb)
    Battery size, quantity BP290, Li-ion, 10.8 V, 2500 mAh, 27 Wh
    Ingress Protection IEC 60529: IP40
    Safety Complies with IEC/EN 61010-1, IEC 61010-2-030, IEC 61010-2-034
    Safety rating CAT III 600 V, CAT IV 300 V
    Performance IEC 61557-1 to IEC/EN 61557-8 and IEC 61557-10

    Voltage measurement AC, DC, and frequency

    Range Resolution Input Impedance Overload Protection
    600 V 0.1 V 320 kΩ 660 V
    45-66 Hz 0.1 Hz 320 kΩ

    Continuity testing (RLO)

    Range (Auto ranging) Resolution Open Circuit Voltage
    20 Ω/200 Ω/2000 Ω 0.01 Ω/0.1 Ω/1 Ω > 4 V

    Insulation resistance measurement (RISO)

    Test voltages
    1672 100-250-500-1000 V
    1673 FC/1674 FC 50-100-250-500-1000 V
    Test Voltage Insulation Resistance Range Resolution Test Current
    50 V 10 kΩ to 50 MΩ 0.01 MΩ 1 mA @ 50 kΩ
    100 V 10 kΩ to 20 MΩ
    20 MΩ to 100 MΩ
    0.01 MΩ
    0.1 MΩ
    1 mA @ 100 kΩ
    250 V 10 kΩ to 20 MΩ
    20 MΩ to 200 MΩ
    0.01 MΩ
    0.1 MΩ
    1 mA @ 250 kΩ
    500 V 10 kΩ to 20 MΩ
    20 MΩ to 200 MΩ
    200 MΩ to 500 MΩ
    0.01 MΩ
    0.1 MΩ
    1 MΩ
    1 mA @ 500 kΩ
    1000 V 100 kΩ to 200 MΩ
    200 MΩ to 1000 MΩ
    0.1 MΩ
    1 MΩ
    1 mA @ 1 MΩ

    Insulation pretest

    Insulation safety pretest Connections from the Tester to L, N, and PE are required.


    Insulation pretestSurge Protection Device (SPD) Insulation RAMP Test (Varistor Test) IEC 61643-11

    Test Voltage Voltage Ranges Resolution Test Current Accuracy
    500 V Step Ramp 0 V to 500 V 1 V 1 mA ± (1.5 % + 3 digits)
    1000 V Step Ramp 0 V to 1000 V 1 V 1 mA ± (1.5 % + 3 digits)

     

    Insulation Monitoring Devices (IMD) IEC 61557-8

    Range Resolution Note
    1 kΩ to 10 kΩ 1 kΩ > 1 MΩ only available with voltages >100 V
    10 kΩ to 100 kΩ 10 kΩ
    100 Ω to 3 MΩ 100 kΩ

    Loop and line impedance (ZI No Trip and Hi Current)

    Range Setting Resolution Accuracy[1]
    10 Ω[2] 0.001 Ω Hi Current mΩ mode: ± (2 % + 15 digits) No Trip (2&3 wire) mode: ± (3 % + 6 digits)
    20 Ω 0.01 Ω Hi Current mode: ± (2 % + 4 digits)
    200 Ω 0.1 Ω No Trip mode: ± (3 %)
    Hi Current mode: ± (2 %)
    2000 Ω 1 Ω ± 6 %[3]
    1. Valid for resistance of neutral circuit < 20 Ω and up to a system phase angle of 30°. Test leads must be zeroed before testing.
    2. Fluke Connect™ 1674 FC model only.
    3. Valid for mains voltage > 200 V.

    Prospective Earth Fault Current (PEFC) Prospective Short Circuit Current (PSC)

    Range Resolution Units
    0 kA to 50 kA IK < 1000 A
    IK ≥ 1000 A
    1 A
    0.1 kA

    Computation: Prospective Earth Fault Current (PEFC/IK) or prospective short circuit current (psc/IK) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.

    Voltage drop (by line impedance test)

    Range Resolution Accuracy
    0.0-99.9% 0.1% Consider accuracy of line
    impedance measurement(s)

    Note: Voltage drop reading is calculated from line impedance measurement & entered current rating

    RCD tests, RCD types tested

    RCD Type[1] 1672 1673 FC 1674 FC
    AC[2] G[3]
    AC S[4]
    A[5], F[6] G
    A, F S
    B, B+[7] G
    B, B+ S
    RDC-DD, RCD A/EV, RCD B/Mi[8]
    GFCI
    1. RCD test inhibited for V > 265 AC
    2. RCD tests permitted only if the selected current, multiplied by earthing resistance, is < 50 V.
    3. AC – Responds to AC
    4. G – General, no delay
    5. S – Time delay
    6. A – Responds to AC and pulsed signal
    7. F – responds to AC, pulsed and high frequency
    8. B, B+ – Responds to AC, pulsed, high frequency, and smooth DC
    9. RDC-DD – Responds to residual currents of 6 mA DC

    RCD tripping time test (ΔT)


    Test Function
    RCD Current Selection
    10 mA 30 mA 100 mA[1] 300 mA[1] 500 mA[1] 1000 mA[2] Var[3]
    x½, 1
    x5
    Ramp
    Auto

    Mains voltage 50 V – 265 V ac, 45/66 Hz

    1. Type B RCDs require mains voltage range of 195 V to 265 V.
    2. Type AC RCDs only.
    3. Type A RCDs are limited to 700 mA, not available for Type B RCDs.

    RCD Tripping Current (IΔN) Measurement/Ramp Test


    Current Range

    Step Size
    Dwell Time Measurement Accuracy
    Type G Type S
    30 % to 110 % of RCD-rated current[1] 10 % of IΔN [2] 300 ms/step 500 ms/step ± 5 %

    1. Specified trip current ranges (IEC 61008-1):

             30 % to 150 % for Type A IΔ N > 10 mA
    30 % to 210 % for Type A IΔ N = 10 mA
    20 % to 210 % for Type B
    50 % to 100 % for Type AC
    35 % to 140 % for Type A (> 10 mA)
    35 % to 200 % for Type A (£ 10 mA)
    50 % to 200 % for Type B2. 5 % for Type B


    Earth resistance test (RE) 1673 FC and 1674 FC only

    Range Resolution Frequency Output Voltage
    200 Ω/2000 Ω 0.1 Ω/1 Ω 128 Hz 25 V

    Phase sequence indication

    Icon  Range Display
    Phase Sequence indicator is active 185 V to 600 V “1-2-3”: or “3-2-1” for incorrect phase

    Models

    Fluke 1672 Multifunction Installation Tester

    Model includes:

    • Multifunction installation tester
    • Heavy duty mains cord with single input connector
    • Hard case
    • USB-C Power adapter for charging
    • Remote control probe
    • Hanging strap
    • Zero adapter
    • Test leads and probes
    • Alligator clips
    • Li-Ion battery
    Fluke 1672 AUS (FLK-1672)
    Fluke 1672 AUS Multifunction Installation Tester
    Fluke 1673 FC AUS (FLK-1673 FC)

    Fluke 1673 FC AUS Multifunction Installation Tester

    Fluke 1674 FC AUS (FLK-1674 FC)

    Fluke 1674 FC AUS Multifunction Installation Tester

    Fluke 1673 FC FTT

    Fluke 1673 FC FTT Multifunction Installation Tester with TruTest Software Bundle

    Fluke 1674 FC FTT

    Fluke 1674 FC FTT Multifunction Installation Tester with TruTest Software Bundle

    1673 FC AUS FTT (FLK-1673 FC-Trutest)

    Fluke 1673 FC AUS FTT Multifunction Installation Tester with TruTest Software Bundle

    Fluke 1674 FC AUS FTT (FLK-1674 FC-Trutest)

    Fluke 1674 FC AUS FTT Multifunction Installation Tester with TruTest Software Bundle

    Fluke 1674 FC 1630

    Fluke 1674 FC 1630 Multifunction Installation Tester with Earth Ground Clamp Bundle

    Fluke 1674 FC AUS/1630 (FLK-1674 FC-1630-2-Trutest)

    Fluke 1674 FC AUS/1630 Multifunction Installation Tester with Earth Ground Clamp Bundle

    Fluke 1674 FC 1630/FTT

    Fluke 1674 FC 1630/FTT Multifunction Installation Tester with Earth Ground Clamp and Fluke TruTest Software Bundle