Fluke 17B Max Digital Multimeter

 

Fluke logo

Fluke 17B Max Digital Multimeter is ideal for both DIY enthusiasts and those starting out in the electrical field as it measures AC/DC voltage up to 1000V and AC/DC current up to 10A, and includes resistance, continuity, diode, and capacitance testing.

With a CAT III 600V rating and built-in overload protection, it provides reliable performance and safety.

Key Features:

  • CAT III 600V Safety Rating
  • AC/DC Voltage and Current Measurements up to 1000V and 10A
  • Resistance, continuity and capacitance measurement functions
  • Diode testing for identifying faulty diodes
  • Large easy-to-read display with bright backlight
  • Input Alert™ Audible and Visual Alarm—Increased Safety

    Fluke 17B Max Datasheet

If you would like more information regarding this product, simply email us here.

  • Enter your query
  • Drop files here or
    Accepted file types: jpg, gif, png, pdf, Max. file size: 1 MB, Max. files: 4.
    • This field is for validation purposes and should be left unchanged.

    Fluke 17B Max Digital Multimeter

    The Fluke 17B MAX Inherits and continues the classic design of 17B+, with further improved functions: Input Alert Alarm, Simple interface to wake meter from sleep mode by activating any buttons, test leads with fine probes to help electricians and electronic R&D personnel make accurate measurements.

    Input Alert™ Audible and Visual Alarm—Increased Safety

    It’s a common mistake to switch to voltage or other functions while the test leads are connected to the current terminals. Doing so can cause the multimeter fuse to blow if a measurement is taken. The 17B MAX includes Input Alert™, which provides both audible and visual warnings to notify users of incorrect operation, helping to prevent blown fuses, reduce productivity loss, and enhance safety.

    Specifications

    Specifications: Fluke 17B MAX Digital Multimeter

    Specifications
    Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 % Accuracy specifications take the form of: ± ([% of Reading] + [Number of Least Significant Digits]).
    Function Range Resolution Accuracy
    15B MAX 17B MAX
    AC Volts (40 Hz to 500 Hz)1 6.000 V
    60.00 V
    600.0 V
    1000 V
    0.001 V
    0.01 V
    0.1 V
    1 V
    1.0 % + 3 1.0 % + 3
    AC Millivolts 600.0 mV 0.1 mV 3.0 % + 3 3.0 % + 3
    DC Volts 6.000 V
    60.00 V
    600.0 V
    1000 V
    0.001 V
    0.01 V
    0.1 V
    1 V
    0.5 % + 3 0.5 % + 3
    DC Millivolts 600.0 mV 0.1 mV 1.0 % + 10 1.0 % + 10
    AC Current μA (40 Hz to 400 Hz)2 400.0 μA
    4000 μA
    0.1 μA
    1 μA
    1.5 % + 3 1.5 % + 3
    AC Current mA (40 Hz to 400 Hz)2 40.00 mA
    400.0 mA
    0.01 mA
    0.1 mA
    1.5 % + 3 1.5 % + 3
    AC Current A (40 Hz to 400 Hz)2 4.000 A
    10.00 A
    0.001 A
    0.01 A
    1.5 % + 3 1.5 % + 3
    DC Current μA2 400.0 μA
    4000 μA
    0.1 μA
    1 μA
    1.5 % + 3 1.5 % + 3
    DC Current mA2 40.00 mA
    400.0 mA
    0.01 mA
    0.1 mA
    1.5 % + 3 1.5 % + 3
    DC Current A2 4.000 A
    10.00 A
    0.001 A
    0.01 A
    1.5 % + 3 1.5 % + 3
    Diode Test3 2.000 V 0.001 V 10% 10%
    Temperature 4 50.0 °C to 400.0 °C
    0 °C to 50.0 °C
    -55.0 °C to 0 °C
    0.1 °C NA 2 %+1 °C
    2 °C
    9 %+2 °C
    Resistance (Ohms)5 400.0 Ω
    4.000 kΩ
    40.00 kΩ
    400.0 kΩ
    4.000 MΩ
    40.00 MΩ
    0.1 Ω
    0.001 kΩ
    0.01 kΩ
    0.1 kΩ
    0.001 MΩ
    0.01 MΩ
    0.5 % + 3
    0.5 % + 2
    0.5 % + 2
    0.5 % + 2
    0.5 % + 2
    1.5 % + 3
    0.5 % + 3
    0.5 % + 2
    0.5 % + 2
    0.5 % + 2
    0.5 % + 2
    1.5 % + 3
    Capacitance6 40.00 nF
    400.0 nF
    4.000 μF
    40.00 μF
    400.0 μF
    2000 μF
    0.01 nF
    0.1 nF
    0.001 μF
    0.01 μF
    0.1 μF
    1 μF
    2 % + 5
    2 % + 5
    5 % + 5
    5 % + 5
    5 % + 5
    5 % + 5
    2 % + 5
    2 % + 5
    5 % + 5
    5 % + 5
    5 % + 5
    5 % + 5
    Frequency1 (10 Hz to 100 kHz) 50.00 Hz
    500.0 Hz
    5.000 kHz
    50.00 kHz
    100.0 kHz
    0.01 Hz
    0.1 Hz
    0.001 kHz
    0.01 kHz
    0.1 kHz
    NA 0.1 % + 3
    Duty Cycle1 1% to 99% 0.10% NA 1 % typical7
    Continuity Threshold 70Ω 70Ω
    Backlight Yes Yes
    1 All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
    2 Typical burden voltage: DC/AC Current µA: 100 µV / µA; DC/AC Current mA: 2 mV/mA; DC/AC Current A: 0.03 V/A
    3Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA
    4Use Type K thermocouple
    5 Typical open circuit test voltage is 0.54 V, maximum short circuit current is 1.8 mA
    6Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
    7 Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %.
    Input Characteristics
    Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
    AC Volts 1000 V 1 >10 MΩ, <100 pF >60 dB at 50 Hz or 60 Hz
    AC Millivolts 1000 V 1 >1 MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
    DC Volts 1000 V 1 >10 MΩ, <100 pF >100 dB at 50 Hz or 60 Hz >60 dB at 50 Hz or 60 Hz
    DC Millivolts 1000 V 1 >1 MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
    1106 V Hz max
    General Specifications
    Maximum voltage between any Terminal and Earth Ground 600 V
    Maximum differential voltage between V and COM terminals 1000V
    Display (LCD) 6000 counts, updates 3/sec
    Battery Type 2 AA, IEC LR6
    Battery life 500 hours minimum
    Temperature Operating 0 °C to 40 °C;
    Storage -30 °C to 60 °C
    Relative Humidity Operating Humidity Non-condensing
    (<10 °C); ≤90 % RH at 10 °C to 30 °C;
    ≤75 % RH at 30 °C to 40 °C
    Operating Humidity, 40 MΩ range ≤80 % RH at 10 °C to 30 °C; ≤70 % RH at 30 °C to 40 °C
    Altitude Operating 2000 m; Storage 12000 m
    Temperature Coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
    Fuse protection for current inputs 440 mA, 1000 V, fast-blow, use only Fluke
    specified parts. 11 A, 1000 V, fast-blow,
    use only Fluke specified parts
    Size (HxWxL) 183 mm x 91 mm x 49.5 mm
    Weight 455 g
    Ingress Protection IP40
    Safety IEC 61010-1, IEC61010-2-030: CAT III
    600 V, Pollution Degree 2
    Electromagnetic Environment IEC 61326-1: Portable
    Electromagnetic Compatibility (EMC) Only applicable in Korea

    Class A Equipment (Industrial Broadcasting & Communication Equipment)1
    1Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.