Fluke 773 Milliamp Process Clamp Meter

$0.00

Fluke logo

The Fluke Fluke 773 Milliamp Process Clamp Meter can measure mA signals without breaking the loop. The Fluke 773 Milliamp Process Clamp provides you with the best in troubleshooting and process calibration power.

Key features

  • Measure 4 to 20 mA signals without breaking the loop
  • Source/simulate 4 to 20 mA signals and provide loop power
  • Source/measure DC voltage to verify power supplies or I/O signals
  • Best in class accuracy of 0.2%
  • Delivers 0.01 mA resolution and sensitivity

    Fluke 772 & 773 Datasheet

If you would like more information regarding this product, simply email us here.

  • Enter your query
  • Drop files here or
    Accepted file types: jpg, gif, png, pdf, Max. file size: 1 MB, Max. files: 4.
    • This field is for validation purposes and should be left unchanged.

    Product overview: Fluke 773 Milliamp Process Clamp Meter

    Save time and money by measuring output signals without shutting down the system

    The Fluke 773 milliamp clamp meter is accurate, versatile, and highly portable. It saves time and money by measuring 4–20 mA signals five times faster than with traditional multimeters, and without breaking the loop. That means you can troubleshoot a live device without having to power down and possibly miss something going on in the process.

    The 773 is ideal for troubleshooting transmitters, valves, and programmable logic controllers (PLCs) found in process plants. The 773 allows you to connect to a mA loop in a traditional series workflow to measure, source, or simulate a control system. And it measures up to 99.0 mA non-contact, including 10 to 50 mA signals in older control systems.

    The 773 also sources and measures DC voltage, so it can be used to troubleshoot voltage input and output devices that accept a 1-5 V or 0 to 10 V signal. You can detach the clamp section of the meter and use it as a remote jaw, connected to the main body by an extension cable to make it easier to take measurements in tight spaces.

    Work smarter with the 778 mA Clamp Meter

    An integrated measurement spotlight allows you to illuminate hard to see wires in dark enclosures while a dual backlit display can show mA measurement and percent of 4 to 20 mA span simultaneously. Use the Hold function to capture measurements on-screen for verification and recording purposes. Plus, automatic power-off features save battery life so you can work longer without changing the batteries.

    Advanced loop troubleshooting

    With the unique mA scale feature users can measure a mA signal without breaking the loop and output that signal to another device to record the measurements. The 773 also includes simultaneous mA in-circuit measurement with 24 V loop power for powering and testing transmitter. You can also apply a mA input signal to a device and measure its 4-20 mA output on devices such as valves or mA isolators. Offers mA or voltage output linear ramp or 25% step output.

    Fluke 773 Features

    • Best in class 0.2 % accuracy
    • 0.01 mA resolution and sensitivity
    • Measure 4 to 20 mA signals without ”breaking the loop”
    • Measure mA signals for PLC and control system analog I/O
    • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
    • Measurement Spotlight illuminates hard to see wires in dark enclosures
    • Detachable clamp with extension cable for measurements in tight locations
    • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
    • Automatically change the 4 to 20 mA output for remote testing
    • Power saving features, auto-off, backlight timeout extend battery life
    • Hold function captures and displays changing measurements
    • Measure 4 to 20 mA signals with in-circuit measurement
    • Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
    • Source 4 to 20 mA signals for testing control system I/O or I/Ps
    • mA output linear ramp or 25% step output
    • DC voltage measurement to verify 24V power supplies or voltage I/O signals
    • Source DC voltage to test input devices that accept a 1-5V or 0 to 10V signals
    • Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp
    • mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal
    • Voltage output linear ramp or 25% step output

    Each Fluke 773 Includes

    • Four AA alkaline batteries (installed)
    • Soft carrying case
    • TL75 test leads
    • AC 72 detachable clip
    • TL 940 mini hook test leads
    • Instruction sheet
    • Hanging tool with hook and loop strap

    Specifications

    Fluke 773 Milliamp Process Clamp Meter

    Specifications

    Diameter of measurable conductor 0.177″ or 4.5 mm max
    Operating temperature -10 to 50ºC
    Storage temperature -25 to 60ºC
    Operating humidity < 90% @ <30ºC, < 75% @ 30 to 55ºC
    Operating altitude 0 to 2000 m
    IP rating IP 40
    Size 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in)
    Weight 410 g, (14.4 oz)
    Vibration Random 2 g, 5 to 500 Hz
    Shock 1 meter drop test (except the jaw)
    EMI/RFI Meets EN61326-1
    For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m.
    Temperature coefficient 0.01% ºC
    (< 18ºC or > 28ºC)
    Power, battery life (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms
    Warranty Three years for electronics
    One year for cable and clamp assembly
    Functional Specifications
    mA measurement
    (measured by clamp)
    Resolution / range 0 to 20.99 mA
    Accuracy 0.2% + 5 counts
    Resolution / range 21.0mA to 100.0 mA
    Accuracy 1% + 5 counts
    mA measurement (measured in series with test jacks) Resolution / range 0 to 24.00 mA
    Accuracy 0.2% + 2 counts
    mA source (maximum mA drive: 24 mA into 1,000 ohms) Resolution / range 0 to 24.00 mA
    Accuracy 0.2% + 2 counts
    mA simulate (maximum voltage 50 V dc) Resolution / range 0 to 24.00 mA
    Accuracy 0.2% + 2 counts
    Voltage source (2 mA maximum drive current) Resolution / range 0 to 10.00 V DC
    Accuracy 0.2% + 2 counts
    Voltage measure Resolution / range 0 to 30.00 V DC
    Accuracy 0.2% + 2 counts

    Using the 773