The Fluke 87-5 Industrial True RMS Digital Multimeter is independently tested to comply with the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V/CAT III 1000V. It can withstand impulses in excess of 8,000 V and reduce risks related to surges and spikes.
New features for maximum productivity.
- Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment (87V)
- Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument (87V)
- Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks
- Large digit display with bright, two-level backlight makes the 80 Series V significantly easier to read than older models
Electrical safety.
All inputs are protected to Category III, 1000 V and Category IV 600 V. They can withstand impulses in excess of 8,000 V and reduce risks related to surges and spikes.
Correctly measure pulse-width modulated motor drive signals.
- The new Fluke 87V is designed specifically to handle complex signals produced by adjustable speed motor drives. Think of the potential productivity you’ll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time. Unique function for accurate measurements of noisy pulse-width modulated AC voltage. Measures correctly at the ASD and at the motor terminals
- Accurately measure the frequency (motor speed). Frequency measurement not affected by the ASDs carrier frequency
- Measure AC current with an optional current clamp accessory
- Compare readings from the 87V with the display on the ASD
- Special shielding blocks high frequency, high-energy noise generated by large drive systems
DCV | |
Maximum Voltage | 1000V |
Accuracy | ±(0.1%+1) |
Maximum Resolution | 100 μV |
ACV | |
Maximum Voltage | 1000V |
Accuracy | ±(0.5%+2) |
AC Bandwidth | 5kHz *with low pass filter; 3db @ 1kHz |
Maximum Resolution | 0.1 mV |
DC Current | |
Maximum Amps | 10A |
Amps Accuracy | ±(0.4%+2) |
Maximum Resolution | 0.01 mA |
AC Current | |
Maximum Amps | 10A |
Amps Accuracy | ±(1.2%+2) |
Maximum Resolution | 0.1 μA |
Resistance | |
Maximum Resistance | 50 MΩ |
Accuracy | ±(0.4%+1) |
Maximum Resolution | 0.1Ω |
Capacitance | |
Maximum Capacitance | 9,999 μF |
Accuracy | ±(1%+2) |
Maximum Resolution | 0.01 nF |
Frequency | |
Maximum Frequency | 200 KHz |
Accuracy | ±(0.005%+1) |
Maximum Resolution | 0.01 Hz |
Duty Cycle | |
Maximum Duty Cycle | 99.9 % |
Accuracy | ±(0.2 per KHz +0.1%) |
Maximum Resolution | 0.1 % |
Temperature Measurement | |
87 V | -200.0°C – 1090°C |
80 BK Temperature Probe | |
87 V | -40°C – 260°C |
Maximum Conductance | 60.00 nS |
Accuracy | ±(1.0%+10) |
Maximum Resolution | 0.01 nS |
Operating Range | |
Operating Temperature | -20°C – 55°C |
Storage Temperature | -40°C – 60°C |
Physical | |
Dimensions | 5.2 cm x 9.8cm x 20.1 cm |
Weight | 624 g |