Kyoritsu 2009R KEW 2009R AC/DC Digital Clamp Meter
The Kyoritsu 2009R AC/DC Digital Clamp Meter has teardrop-shaped jaws for ease-of-use in accessing crowded cable areas and other tight situations. Its data hold function allows easy readings in dimly-lit or otherwise hard-to-read locations. The Kyoritsu 2009R provides a wide measuring range and takes True RMS readings of AC current or voltage with distorted waveform.
Kyoritsu 2009R Features:
- CAT IV clampmeter measures voltage and current in both very low and high power circuits
- Accurate True RMS reading of AC current or voltage with distorted waveform
- Measures AC and DC currents up to 2000 A
- Provides frequency reading in AC current or voltage measurement
- Auto-ranging feature on current, voltage and resistance ranges
- Dynamic range of 4200 counts full scale
- Wide frequency range from 20 Hz to 1 kHz
- Easy continuity checking, with bleeper
- Average function for easy reading of input with large variation
- Peak function for measuring a peak of input
- Auto-null function for easy zero adjustment
- Provides recorder output for long hour monitoring
- Auto-power-off feature to conserve battery power
- 55mm diameter teardrop-shaped jaws
- Shrouded jaws enhance safety
- Terminal cover prevents use of incorrect terminal
- Dimensions 250 x 105 x 49 mm
- Weight 540 g approximately (including batteries)
Kyoritsu 2009R Safety Catagory:
IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution Degree 2, IEC 61010-031, IEC 61010-2-032, IEC 61326-1, IEC 61326-2-1
Kyoritsu 2009R Specifications:
AC A | 400.0/2000A ±1.3%rdg±3dgt (0 – 400.0A, 150 – 1700A) (45 – 66Hz) ±2.0%rdg±5dgt (0 – 400.0A, 150 – 1700A) (20Hz – 1kHz) ±2.3%rdg±3dgt (1701 – 2000A) (45 – 66Hz) |
---|---|
DC A | 400.0/2000A±1.3%rdg±2dgt |
AC V | 40.00/400.0/750V ±1.0%rdg±3dgt (45 – 66Hz) ±1.5%rdg±5dgt (20Hz – 1kHz) |
DC V | 40.00/400.0/1000V±1.0%rdg±2dgt |
Ω | 400.0/4000Ω ±1.5%rdg±2dgt (Electronic protection (no fuse) up to 600V) |
Continuity buzzer | Buzzer sounds below 20Ω |
Hz | 10.0 – 4000Hz±1.5%rdg±5dgt (Input sensitivityCurrent: more than 40AVoltage: more than 10V) |
Conductor size | Ø55mm max. |
Output | Recorder : DC400mV against AC/DC400.0A DC200mV against AC/DC2000A |
Applicable standards | IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2 IEC 61010-031, IEC 61010-2-032, IEC 61326-1, IEC 61326-2-1 |
Power source | R6 (1.5V) × 2 |
Dimensions | 250(L) × 105(W) × 49(D)mm |
Weight | Approx. 540g (including batteries) |
Included Accessories | 7107A (Test leads), 8201 (Output plug), 9094 (Carrying case) R6 (AA) (1.5V) × 2, Instruction Manual |
Optional Accessories | 7256 (Output cord) |