Yokogawa CL340 Features
- Mean value display
- Auto power-off
- Manual range switching
- Approved for comformity to safety standards EN61010-1, EN61010-2-032 (CAT. III 300 V)
Yokogawa CL340 Specifications
Parameter
|
Reference
|
Accuracy
|
|
WIDE(20Hz to)
|
50/60Hz
|
||
AC Current | 40mA/400mA | 2.5+10 (20 to 1kHz) | 1.0+5 (50/60Hz) |
400A(0 to 350A) | 2.5+10 (40 to 1kHz) | 1.0+5 (50/60Hz) | |
400A(350 to 400A) | 5.0 (40 to 1kHz) | 2.0 (50/60Hz) | |
At 23 deg.C ±5 deg.C, 85% RH or less Accuracy: ±(% rdg + dgt) = ±(% readout + value of least significant digit) |
Method of detection | Mean value |
Display | LCD(Digital display:3999 counts) |
Response Time | Approx. 2 seconds |
Range Switching | Manual-range |
Data Hold | On all range |
Peak Hold | On all range |
Ambient temperature and humidity | 0 to 40 deg.C, 85% RH or less (no condensation) |
Temperature Coefficient | _ |
Influence of external magnetic field | 10mA or less in proximity to a 15mm-dia conductor carrying 100A |
Influence of conductor position | 40/400mA range:Within 5dgt at every part inside the jaw400A range |
0 to 250A:Within ±0.5%rdg ±5dgt at every part inside the jaw section | |
Influence of residual current | 12mA or less in proximity to a 10mm-dia conductor carrying 100A |
Safety Standard | Conforms EN 61010-1, EN61010-2-032 |
Circuit Voltage | 300Vrms or less |
Withstanding Voltage | 3.7kV AC for one minute |
Power Supply | R0-3(UM-4) × 2 or LR03 × 2 |
Battery Life | Approx. 40 hours (continuous) |
Consumed Current | Approx. 13mA |
Auto power-off | Approx. 10 minutes |
Diameter of measurable conductor | 40mm at maximum |
Dimensions | Approx. 81(W) × 185(H) × 40(D)mm |
Weight | Approx. 270g |