The Yokogawa TX10-02 Digital Thermometer is a single channel Multifunction with data hold, internal memory, user-calibration and relative display function. It supports K, J, E and I thermocouples.
- Thermocouple measurement ranges (Type K): 200 to 1372°C
- Resolution: up to 0.1°C (under 200°C)
- Resolution select key
- Accuracy: up to ±(0.1% of reading + 0.7 deg.C (-100.0 to 199.9°C)
- Memory stores 10 values
- LCD display
- Rated to IP54 for drips and dust
- Includes batteries and manual
- Similar to Fluke 51-2
Applications
- Temperature management in a refrigerated warehouse
- Temperature checks in equipment maintenance
- Temperature management for research and development
- TX1002 thermocouple thermometers supports K, J, E and T type thermocouples. The single input is a female Mini-Connector compatible with most thermocouple probes
Yokogawa TX1002 General Specifications | |
Number of Input channel | 1 |
Measuring Range | Type E: -200 to 700°C (-328 to 1292°F) Type J: -200 to 1000°C (-328 to 1832°F) Type K: -200 to 1372°C (-328 to 2501.6°F) Type T: -200 to 400°C (-328 to 752°F) |
Resolution | -200.0°C to 199.9°C: 0.1°C or 1°C (when 1°C resolution is set) +200°C or above: 1°C |
Accuracy | +200 °C or above, or when 1°C resolution is set ±(0.2% of rdg + 1°C) -100.0°C to 199.9°C ±(0.1% of rdg + 0.7°C) -200.0°C to -100.1°C ±(0.1% of rdg + 1.0°C) |
Temperature Coefficient | ± (0.015% of rdg +0.06°C)/°C |
Approx. Measurement Interval | 1 sec |
Data Storage | Capable of storing up to 10 measured data items |
Simplified Correction | Correction range: ±20°C of measured value |
Display Item | HOLD, RCD, REL, ADJ, MAX, MIN, MEM, °C chA, TC type K, J, E, T Battery alarm |
Other Functions | Auto power-off, battery alarm |
Display | LCD |
Operating Temperature | 0 to 50 ºC |
Humidity | 80% RH (no condensation) |
Power Requirements | Two AA-size alkaline dry batteries (LR6) |
Battery Life | About 450 hours |
Drip-proof Construction | Conforms to IP54 (dust-proof and drip-proof requirements of IEC529) |
Compliance with Standards | EMC Standards EMI (interference signal): EN55011;1998, EN61326-1;1998+A1 (Class B, Group 1) EMS (immunity): EN50082-1;1997, EN61326;1998+A1 |
Approx. Height | 151 mm |
Approx. Width | 56 mm |
Approx. Depth | 33 mm |
Approx. External Weight | 180 g |
Supplied Accessories | Two AA-size alkaline dry batteries (LR6) and instruction manual |
Optional Accessories | Extension Cable 5 m (2459 21)/10 m (2459 22) Soft case (930 12) Temperature Probes (for K type thermocouple) Rounded end probe (900 20, 900 21, 900 22) Needle probe (900 23, 900 24) Surface probe (900 30, 900 31, 900 32, 900 33) Bead TC (2459 07) Waterproof Cover (5-per package) (930 11) |