The PRESYS T-500PIR Infrared Calibrator generates temperature values in order to enable the calibration of infrared thermometers. The temperatures generated have high accuracy, in an area of uniform temperature and emissivity.
The PRESYS T-500PIR Infrared Calibrator also has input for thermocouples and resistance thermometers, as well as current meter function.
- The T-500PIR generates temperature from ambient to 500 ºC.
- Has input for thermocouples, RTDs and thermoswitches reading.
- The use of external standard thermometer is not required*.
- Carries out completely automatic calibrations with or without the use of a
- Accuracy of up 0.4 ºC, stability of 0.2 °C and resolution of 0.01 ºC.
- Documenting capabilities: communication with computer and ISOPLAN Calibration Software.
- Portable and compact, has strap for easy
* For high performance calibration, it is possible to make use of an external sensor RTD read in the input of the calibrator, with adjustment of the Callendar-Van Dusen coefficients.
It has extensive programming capabilities, where the calibrator is programmed to generate pre-set temperature.
Compatible with automatic calibration and documenting software, with application of ISOPLAN software on PC / Windows platform, using the serial port for connection between the PC and the calibrator that communicate via RS-232 or RS-485. ISOPLAN software can register thermometers and factory instruments, generate work orders, produce and print calibration certificates and reports, that is, all the information of power is brought into the environment of calibrations.
T-500PIR has also many other features, such as:
- The electric signal calibrator is independent from the blackbody target
- Internal buzzer beeps when the temperature reaches the desired
- Keypad that eases the operation and configuration of the
- Vacuum Fluorescent Display to present big-size
- Thermo-element reading scaled to ITS-90 or IPTS-68.
- RTD reading configurable with Callendar-Van Dusen coefficients
- Internal regulated 24Vdc power supply for 2-wire
- Internal rechargeable battery and battery charger included in the electric signal calibrator.
- Independent circuitry for over-temperature protection and
PRESYS T-500PIR Infrared Calibrator Specifications:
Operating Range | ambient to 500 °C |
Power Supply | 110 or 220 Vac, 50/60Hz |
Target Size | 80 mm |
Resolution | ± 0.01 °C |
Accuracy (internal reference) | ± (0.4 °C + 0.1% of reading) |
(external reference) | ± 0.2 ºC |
Target Emissivity (e): | 0.95 ± 0.01 |
Stability | ± 0.2 °C |
Electric Power | 1000 W |
Heating Time | 35 minutes (50 ºC to 500 ºC) |
Cooling Time | 30 min (500 °C to 100 °C) |
Units / temperature Scales | °C or °F / IPTS-68 or ITS-90,
user selectable |
Display | Graphic vacuum fluorescent with
contrast adjustment |
Target Uniformity | ± 0.50 °C |
Dimensions (HxWxD) | 260 x 180 x 270 mm |
Weight | 5.2 kg |
Warranty | One year |
Â
Input Ranges | Resolution | Accuracy | Notes | |
millivolt | -150 to 150 mV
-500 to -150 mV 150 to 2450 mV |
0.001 mV
0.01 mV 0.01 mV |
± 0.01 % FS
± 0.02 % FS ± 0.02 % FS |
Rinput > 10 MWÂ auto-range |
mA | -5 to 24,5 mA | 0.0001 mA | ± 0.02 % FS | Rinput < 160 W |
Resistance | 0 to 400 W
400 to 2500 W |
0.01 W
0.01 W |
± 0.01 % FS
± 0.03 % FS |
excitation current 0.9mA |
Pt-100 | -200 to 850 ºC / -328 to 1562 ºF | 0.01 ºC / 0.01 ºF | ± 0.1 ºC / ± 0.2 ºF | IEC-60751 |
Pt-1000 | -200 to 400 ºC / -328 to 752 ºF | 0.1 ºC / 0.1 ºF | ± 0.1 ºC / ± 0.2 ºF | IEC-60751 |
Cu-10 | -200 to 260 ºC / -328 to 500 ºF | 0.1 ºC / 0.1 ºF | ± 2.0 ºC / ± 4.0 ºF | Minco 16-9 |
Ni-100 | -60 to 250 ºC / -76 to 482 ºF | 0.1 ºC / 0.1 ºF | ± 0.2 ºC / ± 0.4 ºF | DIN-43760 |
TC-J | -210 to 1200 ºC / -346 to 2192 ºF | 0.1 ºC / 0.1 ºF | ± 0.2 ºC / ± 0.4 ºF | IEC-60584 |
TC-K | -270 to -150 ºC / -454 to -238 ºF
-150 to 1370 ºC / -238 to 2498 ºF |
0.1 ºC / 0.1 ºF
0.1 ºC / 0.1 ºF |
± 0.5 ºC / ± 1.0 ºF
± 0.2 ºC / ± 0.4 ºF |
IEC-60584 |
TC-T | -260 to -200 ºC / -436 to -328 ºF
-200 to -75 ºC / -328 to -103 ºF -75 to 400 ºC / -103 to 752 ºF |
0.1 ºC / 0.1 ºF
0.1 ºC / 0.1 ºF 0.1 ºC / 0.1 ºF |
± 0.6 ºC / ± 1.2 ºF
± 0.4 ºC / ± 0.8 ºF ± 0.2 ºC / ± 0.4 ºF |
Â
IEC-60584 |
TC-E | -270 to -150 ºC / -454 to -238 ºF
-150 to 1000 ºC / -238 to 1832 ºF |
0.1 ºC / 0.1 ºF
0.1 ºC / 0.1 ºF |
± 0.3 ºC / ± 0.6 ºF
± 0.1 ºC / ± 0.2 ºF |
IEC-60584 |
TC-N | -260 to -200 ºC / -436 to -328 ºF
-200 to -20 ºC / -328 to -4 ºF -20 to 1300 ºC / -4 to 2372 ºF |
0.1 ºC / 0.1 ºF
0.1 ºC / 0.1 ºF 0.1 ºC / 0.1 ºF |
± 1.0 ºC / ± 2.0 ºF
± 0.4 ºC / ± 0.8 ºF ± 0.2 ºC / ± 0.4 ºF |
Â
IEC-60584 |
TC-L | -200 to 900 ºC / -328 to 1652 ºF | 0.1 ºC / 0.1 ºF | ± 0.2 ºC / ± 0.4 ºF | DIN-43710 |