SEW 6305IN DIGITAL 5kV HIGH VOLTAGE INSULATION TESTER
SEW 6305IN SPECIAL FUNCTIONS
Voltmeter
Conventional insulation testers are highly susceptible to damage when testing insulation resistance while voltage is present on the measured object (whether ACV or DCV). To safely prevent damage, the SEW 6305IN has the unique ability to sense voltage on a measured object.
If any voltage is sensed, the tester will automatically switch to voltage detection mode and display the voltage finding on the LCD screen. This allows the user to prevent damage caused by attempting to measure insulation resistance while voltage is present.
DAR = Dielectric Absorption Ratio
The Dielectric Absorption Ratio is the ratio of the insulation resistance measured at 1 minute divided by the insulation resistance measured at 30 seconds. Thirty seconds after starting a test, SEW 6305IN will beep, indicating that the resistance value measured at 30 seconds has been saved.
One minute after starting a test, the tester will beep again, indicating that the DAR result has been computed. The display format then changes to display the DAR result.
PI = Polarization Index
The Polarization Index is the ratio of the insulation resistance measured at 10 minutes divided by the insulation resistance measured at 1 minute. One minute after starting a test, the resistance value is saved and the DAR is displayed. The test then continues, and after 10 minutes, the SEW 6305IN will beep again, indicating that the PI result has been computed. The display format changes to display the PI result.
Note: Tests on lower insulation resistance take longer, which tends to deteriorate the test specimen. Thus, higher DAR or PI readings (closer to 1) would indicate a better grade of insulation.
SEW 6305IN Specifications:
Test Voltage | 500V, 1000V, 2500V, 5000V | |
Insulation resistance | 1TΩ / 500V 2TΩ / 1000V 5TΩ / 2500V 10TΩ / 5000V |
|
Accuracy | 0~100GΩ / 500V 0~200GΩ / 1000V 0~500GΩ / 2500V 0~1000GΩ / 5000V |
±(5%rdg+5dgt) |
100G~1TΩ / 500V 200G~2TΩ / 1000V 500G~5TΩ / 2500V 1000G~10TΩ / 5000V |
±12%rdg | |
Resolution | 1000MΩ: 1MΩ 10GΩ: 0.01GΩ 100GΩ: 0.1GΩ 1TΩ: 1GΩ 10TΩ: 10GΩ |
|
Short circuit current | up to 5mA | |
PI (Polarization Index) | V | |
DAR (Dielectric Absorption Ratio) | V | |
Voltmeter | ACV: 30~600V (50/60Hz) DCV: 30~600V Accuracy: ±(2.0%rdg + 3dgt) Resolution: 1V |
|
Current measurement |
0.5nA ~ 0.55mA (Depending on the insulation resistance) |
|
Power source | Rechargeable battery | |
AC Adapter | Input: 100-240Vac, 0.4A, 50-60Hz Output: 24Vdc, 0.62A |
|
Dimensions | 330(L) × 260(W) × 160(D)mm | |
Weight | Approx : 3760g |